Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the %arLink for more information
to see all verified strength labels (25)
  • Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)
  • Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
SPD
Installation
Tandem Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Spiral
Material
ZnO
Certification
ISO9001
Brand
Haivol
Rated Voltage
220V
Frequency
50Hz
Rated Discharge Current
10ka
Applicable Site
Outdoor
Transport Package
Cartons
Specification
220v
Trademark
HAIVOL
Origin
China
HS Code
8535400000
Production Capacity
6, 000PCS/Month

Packaging & Delivery

Package Size
6.90cm * 6.50cm * 12.10cm
Package Gross Weight
0.210kg

Product Description

Product Description

The surge protection device connector (SPD) is designed to protect low voltage overhead lines and electric equipment against over-voltages.It enables the current from the lightning to be led to the ground.

The surge protection device includes the following elements:

- An insulation piercing connector(optional).

- A L shape terminal pole connect with IPC.

- A surge protection device (Meta oxide varistor(MVO) moulded with TPU) screwed into the terminal pole.

-A disconnector mounted on the surge protection device's lower terminal

- A grounding wire connected to the disconnector.

-A safety rope that automatically releases and pulls the grounding wire via the disconnector upon surge protective device failure..

 

When a surge protective device (SPD) encounters a transient overvoltage (such as a lightning surge), it rapidly switches its impedance from a high-resistance state to a low-resistance state. This action diverts the surge current to the ground, thereby clamping the voltage across the protected line to a safe level (known as the residual voltage).

 

Conversely, if the leakage current flowing through the SPD under normal grid voltage continuously increases and exceeds 1mA (or another specified threshold), it indicates that the SPD may have degraded and requires monitoring or replacement.

 

When an internal short-circuit failure occurs in a surge protective device (SPD), the continuous power-frequency current from the grid passes through the disconnector, generating significant heat. This heat melts the low-temperature solder joint inside the disconnector.

The melted solder joint releases a pre-compressed spring. The mechanical energy of the spring then forcibly severs the grounding connection point between the SPD and the disconnector, completely isolating the failed SPD from both the power grid and the earth.

Simultaneously upon disconnection, the disconnector's red casing detaches and hangs down with the grounding wire under gravity. This provides a clear visual indication, allowing maintenance personnel to quickly identify the faulty SPD from a distance and promptly replace it.

 

 

Characteristic Description:

The surge protection device is used outside only.

- The maximum use altitude is 2000m.

- It can be used at a temperature going from -40°C to +70°C.

- The use frequency is 48-62Hz.

- The L shape terminal pole, the surge protection device and the disconnector are made of UV and flame resistant materials.

- It equipped with a 0.5m long, 6mm² insulated black multi-stranded grounding wire.

- Protection degree is IP67.

- Comply with IEC 61643-1 standard.
 

Product Parameters

 Rated voltage

V

 

220

 Maximum Continuous Operating Voltage Uc

 

V

 

280

 Frequency

Hz

 

50

Rated discharge current

kA

 

10

Residual voltage on a surge arrester with an 8/20μs wave, 5kA

kV

 

≤1.1

-Residual voltage on a surge arrester with an 8/20μs wave, 10kA

kV

 

≤1.2

-Residual voltage on a surge arrester with an 8/20μs wave, 20kA

kV

 

≤1.5

Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)
Low Voltage Outdoor Oxide Lightning Arresters on Overhead Lines (SPD)
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now