High Performance Polymer Insulators for Electrified Railways

Product Details
Customization: Available
Application: High-voltage
Material: Composite Polymer
Still deciding? Get samples of US$ 1/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • High Performance Polymer Insulators for Electrified Railways
  • High Performance Polymer Insulators for Electrified Railways
Find Similar Products

Basic Info.

Model NO.
FQX
Structure
Suspension Insulator
Type
B Type Insulator
Usage
High Voltage Power Transmission, Insulation
Connection Method
Spherical Type
Size of Bearing Capacity
550KN
Certification
CCC, CE, ISO9001
Color
White
Brand
Haivol
Insulation Material
Silicone Rubber
Type of Couple
Socket and Ball
Transport Package
Carton
Specification
111
Trademark
HAIVOL
Origin
China
HS Code
3917310000
Production Capacity
200, 000PCS

Packaging & Delivery

Package Size
155.00cm * 66.00cm * 200.00cm
Package Gross Weight
2.200kg

Product Description

Composite insulators for electrified railways

 

Composite insulators for electrified railways have compact structure, strong integrity, good anti-fouling ability, light weight, small size, good internal and external insulation performance, high mechanical strength, and no need for regular cleaning. They are mainly used for high-speed railway and urban light rail transportation construction.

 

Composite insulators for electrified railways also named railway insulators, electrified railway catenary parts, polymer insulators for electrified railways, railway polymer insulators.

 

The support arm is made of stainless steel material or Hot dip galvanized cast steel, which has better anti-corrosion performance. It solves the corrosion of products under various climatic conditions such as humidity and acid rain. It can greatly extend the life of the product and provide reliable equipment for the implementation of compact circuit construction.

 

Electrified railways Composite insulators is suitable for electrified railway tunnels with complex operating conditions, which can effectively prevent pollution flashover accidents and reduce the workload of cleaning and maintenance. Due to its small size, when the tunnel clearance is small, it is a product that porcelain and glass insulators cannot replace. 

 

Technology characteristics:

1)The silicone rubber housing taken shape by whole injection has good hydrophobicity, drophobicity migration and soil resistance, as well as excellent electrical insulation roperties and aging resistance, which could prevent effectively those accidents of pollution flashovers so as to ensure the safe running of high voltage transmission lines.

2)The modified ECR fiberglass reinforced epoxy resin rod is used as it has good resistance to high temperature, stress corrosion &acid attack, as well as fine damping action, high tensile strength( >1200Mpa ) and resistance to creep and fatigue failure, which effectively ensure the internal insulation quality and mechanical strength of insulators.

3)End fittings are crimped onto fiberglass rod with voice-operated displacement type crimper , The insulators with this crimping technique have high mechanical strength and small dispersion.

4)The connection location between end fittings & rods is fused with sheds housing by the overall high tempera- ture vulcanized silicone rubber injection molding as it could minimize the interface. 

5)The internal radial multi-seal structure effectively guarantees a long-term reliability of seal around the connection between end fittings & rods.

 

Note:

1 Applicable stardand:IEC,ANSI,GB and other international standard

2 Normal colour of the composite insulator:red,gray and white.

3 Special design according customer's requirement.

 

Main Technical Parameter
Model

Structure height

 H(mm)

Nominal creepage distance

 L(mm)

Design creepage distance

 L(mm)

Nominal dry arc distance

(mm)

Design dry arc distance

(mm)

Rated mechanical tensile failure load(KN) Standard lightning impulse withstand voltage peak(KV) Public frequency dry withstand voltage(KV) Public frequency wet withstand voltage(KV) Artificial pollution public frequency withstand voltage(KV)
FQX-25/100(120)QT 700±20 1200
 
1300
 
500
 
511
 
100(120)
 
270 160 130 36
FQX-25/100(120)QH 700±20
FQX-25/100(120)HH 700±20
FQD-25/100(120)HY 734±20
FQX-25/160QT 750±20 512
 
160
 
31.5
FQX-25/160QH 750±20
FQX-25/160HH 750±20

 


High Performance Polymer Insulators for Electrified RailwaysHigh Performance Polymer Insulators for Electrified RailwaysHigh Performance Polymer Insulators for Electrified RailwaysHigh Performance Polymer Insulators for Electrified RailwaysHigh Performance Polymer Insulators for Electrified Railways
High Performance Polymer Insulators for Electrified Railways

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier