• 15kv 630A High Voltage Disconnector Switch
  • 15kv 630A High Voltage Disconnector Switch
  • 15kv 630A High Voltage Disconnector Switch

15kv 630A High Voltage Disconnector Switch

Type: High-voltage
Structure: Single-column Disconnector
Installation: Outdoor High-voltage
Operation: Manual
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
15KV 630A
Number of Poles
Three Pole
Grounding
Single Ground
Series
Single-Stage
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
YR
Structure of Operating
Manual
Certification
ISO, IS9001
Brand
Haivol
Outdoor Installation
Single Phase
Transport Package
Carton
Specification
ANSI, IEEE, IEC
Trademark
HAIVOL
Origin
China
HS Code
3917310000
Production Capacity
500PCS/Month

Product Description

product brief introduction
In electrical engineering, a disconnector, disconnect switch or isolator switch is used to ensure that an electrical circuit is completely de-energized for service or maintenance. They are only used for breaking the circuit and are often found in electrical distribution and substation, where machinery must have its source of driving power removed for adjustment or repair. Disconnectors can be manual or motor operated and may be paired with an earthing switch to ground the portion that has been isolated from the system for ensuring the safety of equipment and the personnel working on it.High-voltage isolation switches are used in electrical substations to allow isolation of apparatus such as circuit breakers, transformers, and transmission lines, for maintenance. The disconnector is usually not intended for normal control of the circuit, but only for safety isolation. Unlike load switches and circuit breakers, disconnectors lack a mechanism for suppression of electric arcs, which occurs when conductors carrying high currents are electrically interrupted. Thus, they are off-load devices, with very low breaking capacity, intended to be opened only after the current has been interrupted by some other control device.

Specification:
Rated voltage: 15KV
Rated current: 400A/630A
15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch15kv 630A High Voltage Disconnector Switch
15kv 630A High Voltage Disconnector Switch
15kv 630A High Voltage Disconnector Switch
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now