• (RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
  • (RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
  • (RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
  • (RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch

(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch

Transport Package: Wooden Case
Specification: FW1-12/24/36
Trademark: haivol
Origin: China
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RH-B-11/33KV
HS Code
3917310000
Production Capacity
10000

Product Description

product brief introduction
In electrical engineering, a disconnector, disconnect switch or isolator switch is used to ensure that an electrical circuit is completely de-energized for service or maintenance. They are only used for breaking the circuit and are often found in electrical distribution and substation, where machinery must have its source of driving power removed for adjustment or repair. Disconnectors can be manual or motor operated and may be paired with an earthing switch to ground the portion that has been isolated from the system for ensuring the safety of equipment and the personnel working on it.High-voltage isolation switches are used in electrical substations to allow isolation of apparatus such as circuit breakers, transformers, and transmission lines, for maintenance. The disconnector is usually not intended for normal control of the circuit, but only for safety isolation. Unlike load switches and circuit breakers, disconnectors lack a mechanism for suppression of electric arcs, which occurs when conductors carrying high currents are electrically interrupted. Thus, they are off-load devices, with very low breaking capacity, intended to be opened only after the current has been interrupted by some other control device.

Specifications
Outdoor Gang Isolator Switch 
1.Rated voltage:11/33KV 
2.Rated current:400/600A 
3.Standard:IEC60964:1996/IEC62271-102:2002 

Outdoor Gang Isolator Switch Model RH-B-11/33kV 
Outdoor AC Gang isolator switch 11kv/400A-33kv/600A used in 3 phase AC 50/60Hz power circuit, it is used as switching on and switching off at the voltage with no load. It apply to IEC standard. IEC60964: 1996, IEC62271-102: 2002.
 
Technical Specification
Type Rated 
voltage
(KV)
Rated 
current
(A)
4S Heat 
steady 
e. c. A
Impulse 
withstand 
voltage A
Impulse voltage Power frequency 
withstand voltage
To earth 
(KV ) 
Across the 
isolating 
distance (KV)
To earth 
(KV ) 
Across the 
isolating 
distance(KV)
RH-B 11 400 12500 31500 75 95 38 42
33 600 12500 31500 170 195 70 80
 

Participate in the exhibition pictures
(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
(RH-B-11/33KV) Outdoor Gang Isolator Switch/Air Breaking Isolationg Switch
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now